What phenomena might occur if lack of power supply?
1) ICR switches frequently.
2) The camera’s image looks dark.
3) Some ripples appear in the image.
4) The camera might reboot frequently.
Why is the camera’s image unclear?
1) Unmatched lens mount. There are two types of lens mount for box
cameras,respectively are CS mount and C mount, the lens and camera must
be matched with the same type.
2) Use Focus in / focus out to control the Clarity.
3) Check whether the lens or housing gets dirty.
4) In case of strong light condition, please select electronic iris as the lens type.
What is SMART Face Detection?
Face Detection: Face Detection function is fulfilled by the camera. The face features such as eyes and mouth would be recognized. The detection highly demands the size of face shown in the image and the angle to the lens. We recommend users have the camera installed close to the desired detection region and make sure people face the camera directly. Notice: Face Detection is different from Face Recognition. In Face Detection, the detection of faces in the whole image would trigger the alarm and notify surveillance center. The regions of detected faces would not be captured. The Face Recognition Camera is able to capture face images and upload to server for face comparison.
If I forgot the password of ZKTeco IP camera, how can I login in the Client software?
Why our DVR/NVR cannot find the HDDs?
Please install the HDD properly, no gap with the interface. Please install recommended HDD, eg. Seagate, WD, TOSHIBA, SANSUNG, HITACHI (generally capacity: 1T, 2T, 4T, 6T, 8T).
What is Main stream / Sub stream?
The main stream with high resolution and full frame rate can be used for main monitoring and recording. The sub stream with lower resolution can be used for mobile monitoring. Some devices support third stream which offers more flexible choices.
What are Stream and Bitrate?
After the video is compressed, a stream is generated. Bitrate (bps): quantity of bit stream per second. Bitrate type: Constant Bitrate (CBR), Variable Bitrate (VBR). Stream type: video, audio, video & audio complex stream.
What is DVR / NVR?
DVR/NVR is a management device which realizes the function of centralized storage, local live view, search, playback and other functions. The main difference between DVR and NVR is the function of encoding. DVR is an encoding unit, but NVR does not have this feature.
What is ONVIF?
ONVIF is committed to providing and promoting open interfaces to the security industry for effective interoperability of IP-based physical security products.
What is Resolution?
Resolution is usually measured by the number of horizontal and vertical pixels. It can be expressed as number of horizontal point * number of vertical pixels. In a fixed plane, the higher resolution could provide better image.
What is PoE Power Supply?
Only the network camera has POE. 1,2,3,6 are the data wire and 4,5,7,8 are idle. Two methods can be applied. With 8-core wire, one method is using 1-4 cores for both power supply and data transmission. Another method to use 5-8 cores for power supply while the rest for data transmission.
What does 4K mean?
The name "4K resolution" refers to a horizontal resolution of approximately 4,000 pixels. It has been developed into a variety of standards. The DCI 4K resolution standard (4096 * 2160 pixels) is widely respected by the film and video production industry. Besides, UHDTV standard (3840 * 2160 pixels) is also popular which has twice the horizontal and vertical resolution of 1080p (as shown in the figure below).
If I forgot the password of DVR / NVR, how can we login in DVR / NVR.
Please send us the snapshot of DVR/NVR screen with clear date and time (as below),we will give you a super password to login in the DVR/NVR.
ZMM100 Mifare device, if enroll card both in user manage menu, and Card management menu.it will verify failed.
After test we found, that if you just enroll from user mng, or card mng menu, it can verify succeed, If enroll from user management, then enroll again from card management, it will ask copy data to card or not, if we choose no, it could not verify succeed on device. But if we choose yes, we could still verify succeed. If meet this issue, just tell customer to enroll from one of the menu.
customer enroll 3297 fingerprint in Alg 9.0,every time when they verify fingerprint, the device will ask for user ID.
In Alg 9.0, if extend 3000 FP, the device will force to 1:1 mode, In this case,we would like to suggest customer to use Alg 10.0.
Can we set whether the work code must be entered when the employee verifies? And how to transfer the work codes from one device to another?
Please go as follow to choose the work code options Menu->Work Code->Work Code Option->Work Code Required ( turn it “On”.) How to transfer the work codes from one device to another? Please go as follow: 1)Download the work codes from device A: USB Manage->Download->Work Code. Upload the work codes from device A to device B: USB Manage->Upload->Upload work code.
If I have used the usb client function on the device, then can I use the wifi function?
These two functions are not compatible with each other. Only when the usb client function is closed, then the wifi function can be used.
If I have open the GPRS function of the device, then can I use the print function
These two functions are not compatible with each other. Once the GPRS function is used, the print function can not be used.
Can we set a certain time to download the logs, and then delete the logs in the device automatically instead of deleting manually?
Please firstly go as follow in the ZKtime.net software: System->Plan Task. Then please go as follow in the ZKtime.net software: System->General.
How to connect the device with the Zktime.net software?
Firstly, please go as follow: menu->Comm->Ethernet(Set the “IP Address”, “Subnet Mask”. “Gateway”. And the TCP COMM port should be 4370). Secondly, please go as follow: menu->PC Connection->Comm Key to be “0”. Thirdly, please go to the zktime.net software, and set as follow: (Let the port to be “4370”, And the pwd to be blank)
How to import the user information from the device to the software via U disk?
Firstly, please download the user information with the U disk. Then please go as follow in the Zktime.net software: Attendance->Import / Export->Import Employees.
If the device needs to change its attendance status automatically, how to achieve that?
Please go as following: menu->Personalize->Shortcut key mappings->Set switch time. Then the status will automatically change when it reaches the time you set.
How to enter ADMS with URL mode? Where to input the port when using the URL mode?
Please go as following to set: menu->COMM->ADMS. And pls turn the “enable domain name” to be “on”, and about the port, pls directly input it together on the domain name such as “abc:8081” in the server address.
Can I take a photo of the user if his fails to verify for continuously three times?
Yes, Please go as the follow path to do some settings: menu->System->Attendance->Camera mode->Save on failed verification.
How to save the illegal verification record.
Please go to the follow path to turn on this function: menu->System->Attendance->Save Illegal Verification Record (Turn it on).Then the device will keep the record though it is illegal.
How to change the advertising pictures of the device?
Create a new folder named "advertise" in the root directory of U disk and place advertising images into the folder. A maximum of 20 images can be stored and the size of each image cannot exceed 30 KB. There are no restrictions on the image’s name and type.
If the device connects with a printer, how to set the printer function on the device? Can the paper be cut automatically when it comes out?
Please go as the follow path: menu->Print->Printer Options->Print (On)->paper cut (If you need it, turn it as“on”) , Then go as below: menu->Print->Data Field Setup (choose to turn on those functions you need.) Thirdly, go to Menu-->Comm.-->RS232/485 and select baud rate. Here is the connection between the device and the printer.
How to change the wallpapers of the device?
Upload the jpg documents with “1~10.jpg” as initial letters of document names stored in a U disk to the terminal. After the upload, these pictures can be displayed on the interface of the terminal. Create a new directory named "wallpaper" in the root directory of U disk and place wallpapers into the directory. A maximum of 20 wallpapers can be stored and the size of each wall paper cannot exceed 30 KB. Pls go as the follow path to upload: menu->USB Manager->Upload->Wallpaper.
There is a triangle together with a red “!” on the top of the main screen, how to cancel it?
It is a signal of the Alarm when the device is getting down from the wall. When the device is installed on the wall normally, this signal will disappear automatically.
How to use wifi with new firmware device?
Pls go as follow: menu->COMM->Wireless Network
Can we set the valid date for the employee?
Please go as follow: menu->User Mng->New User->User Expiration Rule->Expired Date->Start Date->End Date. If the user verifies outside the date, the device would say “invalid user”.
Can FR1200 support Ver9.0? Can FR1200 be connected with C3?
NO, FR1200 can only support Ver10.0; FR1200 can not be connected with C3, because C3 does not support fingerprint.screen, how to cancel it?
How to get the license after reinstall ZKTimeNet 3.0 on another computer
After the computer is replaced ,the licnese have to sent to the licnese issuer for reset. The default is that each licnese of customer have a chance to replace license for free.
What the customer needs to do:
1-send the old Activation file to yo technical support or sales.
2-your company name and country.
The method of restoring database when reinstalling net3.0 is sent to you as an attachment. Please check it.
Method of restoring database when reinstalling net3.0.pdf
why the device shows GPRS online BUT failed to connect to BS software
Check the Sim Card. Some card requires to open data first even it shows online and shows the data transfer, make sure that you could use the SIM card login FaceBook or anyother web. After , insert the SIM card back to device
Uface800 auto restart
Check fingerprint reader and camera. Replace damage fingerprint reader or camera. Pay attention to replacing the correct type of fingerprint reader or camera.
The mysql database was selected when installing BioTime 8.0. An error occurred: unknown error.
Ignore errors,and after the successful installation,reconfigure in the console.
Access3.5 sets the authentication mode, VF300&MB360 does not change
The VF300 & MB360 products are time and attendance terminals with simple access control.
The operation of modifying the verification mode on the Access 3.5 software is for the access control.Therefore, the software is set up and the device has not changed.
Only devices with advanced access control can synchronize the authentication settings on Access 3.5 to the device.
Device can not connect ZKBio TIme
phenomenon :
In theZKBio Time, the device state is online.,but cannot show device model and the version information,and the device name is still auto add.
Solution:
Just click the auto add, and add an new name to device,then the device information will be appears completely.
Big Device capcity
For a big device capcity. You can make a mark with the sales first before you make the new order.
And if you want to upgrade the capcity in your hand , please contact with the supplier to know whether we can do it or not.
Login the webserver3.0 of device
the webserver address is your device ip address.
If the device doesn't have admin, the login accout and the password of the web 3.0 are administrator and 123456.
If your device contains admin user, the login accout and the password are the admin user's ID and password.
Cloud Server Setting (ADMS) shows Disabled.
Contact technical support to set device parameter:ServerType=0
What is dry mode and wet mode ?
The control panel supports “dry mode” and “wet mode” by using the jumper. For “wet mode”, short 2-3 and 4-5 terminals. The control panel and the lock use the separate power supply. One is connected with +12V and GND of POWER interface (for the control panel), the other is connected with V+ and V- of LOCK interface (for the lock). The factory default jumping is set as dry mode.
which reader of the inbio controls which door?
About C3-200, the reader1 and reader3 are the in of lock 1 and lock 2; reader 2 and reader 4 are the out of lock 1 and lock 2. About C3-400, all of the readers are for the in of the lock. When C3-400 changes to two-door two-way, the reader 1 is for the in of lock 1, the reader 2 is for the out of lock 2; the reader 3 is for the in of lock 2, the reader 4 is for the out of lock 2. If for inbio, the odd number is for in of the lock, the even number is for out of the lock.
Inbio+FR1200,can FR1200 be used to register users?
FR1200 can not be used to register fingerprint, it can only be used for verification. Fingerprint sensor such as ZK4000,ZK4500 can be used to register users. The ZK4000 can be used only in 32 digits system; but ZK4500 can be used both in 32 digits and 64 digits.
How to cancel the event records in the inbio?
The event records can not be cleared; when it reaches 100,000, it will overlap the before ones.
The number 7 is used to restore to the factory setting, which kind of data will be initialed? Including the parameters setting?
If you forget the device IP or the device can not work normally, You can use the number 7 terminal to restore inbio460 to factory Setting , the configuration include device IP , communication password ,gateway ,subnet mask. The device IP will be 192.168.1.201,the communication password will be blank. And the parameters setting will not be changed, will stay at the device.
How to reset the device to the factory setting?
The number7 digit is off by default. When it is moved upwards and downwards for three times within 10 seconds and finally returned to OFF position, the factory settings will be restored after the access control panel is restarted.
Inbio260 can only support one FR1200? How to set the 485 address of FR1200?
Inbio260 can at most support four FR1200, two as in, two as out. There are six DIP terminals , 1-4 is for RS485 address , 5 is reserved , 6 is for extending the length of RS485. Set the odd number is for enter reader, and the even number is for exit reader (for example , two readers for one door- the rs485 address 1 is for enter door, rs485 address 2 is for out door) And both 1 and 2 should be translate into the binary digits.
access the access control device directly without the use of ZKTeco software, using c#
This is the download link for the SDK:
https://www.zkteco.com/en/search?keywords=standalone%20SDK
TF1700 doesn't push oplog
The reason is wrong timestamp, delete / data / oplog.dat and restart device,run demo,it will start to push oplog.
ZKBioSecurity and Set Valid Time of 7B
When we want to use 7B's Set Valid Time, we need to enter the device's menu, open the setting (Expiration Rule end setting).
The menu path is:
Menu->System Setting ->Access control record settings->Expiration Rule end setting :
When using ZKBio Access and license has been activated,but get the error: "The points in the system mismatch with the licence points"
Please click on cancel and active again.
Defective touching ( Projected Capacitive touchscreen)
1. The wire connecting touchscreen with main board is defective, the
control card of touchscreen or the internal USB is defective, or the
Operation System is broken. Check all possible reasons above one by one,
then change accordingly.
2. Change the control card, or change touch screen
3. Change touchscreen
Change touchscreen
Defective touching ( Resistive touchscreen )
1. No touching drive, the wire connecting touchscreen with main board is
defective, the control card of touchscreen or the internal USB is
defective, or the touchscreen itself is defective. Check all possible
reasons above one by one, then change accordingly.
2. Try the operation of 9 or 25 points linearity correction, if still
cannot work, probably the control card or touchscreen is defective, need
to change touchscreen
3. Try the operation of 9 or 25 points linearity correction, if still
cannot work normally, probably the control card or touchscreen is
defective, need to change touchscreen
Change touchscreen
Defective display
1. Change LCD
2. Screen line is broken, or BIOS setting is incorrect, or change LCD
3. Change LCD
LCD or LCD backlight is defective, change LCD.
Able to boot and fail to access the operating system
1. Reinstall operation system, ensure all important data is kept safely.
2. Starting up in security mode, antivirus checking, or reinstall operation system.
3. Pull out hard disk and insert again
4. Reboot operating system
Change new hard disk
Unable to boot and power indicator is on
1. Change Main board Pull RAM bank out and insert again, or change RAM bank
Unable to boot and power indicator light is not on
1.Checking power outlet 2.Change adapter 3.Check electric line from main board or change main board Change switch or the cable
If the fingerprint reader does not work, how do we know where the problem is?
1) Confirm the fingerprint reader firmware version, which can be read using a small program.
2) Confirm the software used and its ZKFinger SDK version.
3) Is the released ZKFingerSDK 5.3Lite demo version normal?
4) Provide test steps, video or error screenshots as much as possible.
The following exe can not run: C:\Necsis2\Liberaciones\NEC_FPExtract_X64_20180116\NEC_FPExtract_X64_20180116>sa mple.exe
The application has failed tostart, because its side-by-side configuration is in Use sxstrace to track issues: Sxstrace trace -logfile:trace.bin Then open the application, this time in the trace.bin root directory has been generated, so exit sxstrace, Run the following command again: sxstrace parse -logfile:trace.bin -outfile:trace.log You can see related information. The current check found is the C++ runtime library that has been installed by the customer
The source code in the python DEMO is handed and compiled with exceptions. Prompt missing files, such as ZKFPEngXControl_TLB.
You need to install the Biokey.ocx control in Delphi. After installing the ZKFinger SDK5.3 Lite driver, Biokey will be stored in the program directory, for example: C: Program Files FPSensor Biokey.
When integrating the SLK20R into an Android application, customers cannot find liblibzkfp.so for the ZKFPService class in the JAVA SDK.
Demo error: 'System.Runtime.InteropServices.COMException' occurred in System.Windows.Forms.dll Additional Information: Unregistered class (HRESULT exception: 0x80040154 (REGDB_E_CLASSNOTREG))
Unregistered class, confirming the client's operating system and the number of used SDK bits, suggesting that the client's debugging platform be changed from x64 to x86
The ZKFingerModuleSDK command MD_READ_USER can only obtain the number of templates when acquiring user data from the SLK20M. Cannot obtain the template number?
The ZKFingerModuleSDK command MD_ENROLL_TMP issued a fingerprint to SLK20M failed.
When the command issued a fingerprint, base64 format encoded fingerprint needs to be decoded
Does ZKFingerSDK provide fingerprint template conversion interface?
ZKFingerSDK is not provided, there is another conversion library that can provide conversion interface.However, only ZK10.0 fingerprint templates are currently supported for conversion to ISO/ANSI templates. ISO conversion to ZK fingerprints is not supported.
How to get a 300*400 fingerprint image?
Need to use PIV standard SLK20R
How big USER ID does the SLK20M support?
Our biometric identification SDK does not involve user IDs.Since a person has 10 fingerprints, we only have a finger index, which is a 32-bit unsigned integer, a pure number that does not exceed 9 in length. Our SDK only cares about the information he collects, then compares it and does not care about logical data.
Is it possible to convert our 10.0 fingerprint template into a picture (jpg, png, etc)?
Fingerprint template can't convert pictures. The binarization process of extracting fingerprint feature points from a picture and saving it as a fingerprint template is irreversible.We can get the original fingerprint image from the fingerprint reader through the SDK interface ZKFPM_Acquire Fingerprint Image. It does not support converting from a fingerprint template to a picture.
Fingerprint comparison always fails
1. Confirm whether the fingerprint template of the customer is correct
2. Confirm that the customer's own development process has judgments on
algorithm library initialization and fingerprint reader connection. The
algorithm library initialization may fail but the client still invokes
the comparison interface.
Connected fingerprint reader and not, the result is not the same
Due to the limitation of the algorithm, a fingerprint reader must be connected in order to initialize the algorithm library and the comparison interface can be invoked.
When installing the ZKBiolock on the win10 pro operating system, the software prompt database is incompatible with the operating system.
First install the SQL Server2012 database and then install the ZKBiolock, and configure the database in the software.
EU01 can't get card number from external wiegand reader
It shows "invalid card number" when you try to register card number for a new user. Need to close parity check of wiegand reader,set parameter ExtNeedParity to 0.
External alarm doesn't work on K30 PRO
Check if you have access control menu,you can have access control function or external alarm,only one of them. When you have access control function disabled,you will see the menu in system setting to switch internal/external alarm.
ZKBioSecurity3.0 trial information
For ZKBioSecurity3.0 , it offer 30 days for you to test , no need to get the license. you are free at the first 30days after installed . And if you don't think it is enough for you , you could check the demo link in our website to test more.
When using ZKBio Access and license has been activated,but get the error: "The points in the system mismatch with the licence points"
Please click on cancel and active again.
This website uses cookies to store information on your device, cookies can enhance your user experience and help our website work normally.
For more information, please read our
Cookie Policy and Privacy Policy.